1. Introduction
1-3
1.2.2 Multiple workstation configuration
In the multiple workstation configuration, there can be two workstations connected together by a Local Area
Network (LAN). In this configuration, one workstation is used as the "sensor source" for navigation sensors and the
other workstation is used as the sensor source workstation to communicate with sensors, receiving and transmitting
data from/to workstation via the LAN. In the multiple workstation configuration where navigation sensors are
connected to two workstations, the sensor source may be changed and still receive and transmit information from/to
the system and to/from navigation sensors.
ECDIS Monitor
MU-201CE
(FEA-2107)
or
MU-231CE
(FEA-2807)
ECDIS PROCESSOR
EC1000C
LAN-ADAPTER
EC-1010
LAN-ADAPTER
EC-1010
B-ADAPTER
EC-1020
ARPA RADARS
POSITION-FIXING EQUIPMENT
TRACK PILOT
LOG/DUAL AXIS LOG
AIS
GYRO COMPASS
POSITION EQUIPMENT
ENGINE CONTROL
ECHOSOUNDER
WIND SENSOR
WATER TEMP. METER
AMWSS
GYRO COMPASS
(SYNCHRO, STEPPER)
LOG (200P/NM)
ANALOG INPUT (8 CHANNELS)
ANALOG OUTPUT
100-230 VAC
100-230 VAC
HUB-
100
100-230 VAC
24 VDC
24 VDC
24 VDC
RADAR OVERLAY PCB
ECDIS PROCESSOR
EC1000C
LAN-ADAPTER
EC-1010
LAN-ADAPTER
EC-1010
B-ADAPTER
EC-1020
ARPA RADARS
POSITION-FIXING EQUIPMENT
TRACKPILOT
LOG/DUAL AXIS LOG
AIS
GYROCOMPASS
POSITION EQUIPMENT
ENGINE CONTROL
ECHOSOUNDER
WIND SENSOR
WATER TEMP. METER
AMWSS
GYROCOMPASS
(SYNCHRO, STEPPER)
LOG (200P/NM)
ANALOG INPUT (8 CHANNELS)
ANALOG OUTPUT
OPTION
EXTERNAL
DEVICE
HUB-
100
100-230 VAC
24 VDC
24 VDC
RADAR OVERLAY PCB
ECDIS Monitor
MU-201CE
(FEA-2107)
or
MU-231CE
(FEA-2807)
100-230 VAC
RADAR 1 (VIDEO, HL, AZ)
Selector
RADAR 2 (VIDEO, HL, AZ)
Control Unit
RCU-018
or
Control Unit
RCU-015
Remote Control Unit
RCU-016
Control Unit
RCU-018
or
Control Unit
RCU-015
Remote Control Unit
RCU-016
Category of Units: All units protected from weather
FAR-2xx7
series radar
FAR-2xx7
series radar
Selector
PRINTER
(USB)
PRINTER
(USB)
24 VDC
Conning Monitor
MU-201CE
or
MU-231CE
RADAR 1 (VIDEO, HL, AZ)
RADAR 2 (VIDEO, HL, AZ)
CALCOMP
DRAWING-
BOARD III
DIGITIZER
100-230
VAC
100-230
VAC
Multiple workstation with connection to navigation sensors