8. Vector Chart Material
8-22
Conversion errors, but the chart is partly usable as NON ENC
Use cell status to check details of errors. Note that the chart is no longer ENC if it was produced by a Hydrographic
Office. You must refer to a paper chart as legal primary aid of navigation, when you navigate in the area covered by
this chart.
Successful auto. conv with errors: ENC: n1302322.000, edt: 1, upd: 0 / 1999 1 4 NON ENC
Failed conversion
Chart is not usable and you cannot view the chart. You must refer to a paper chart as legal primary aid of navigation,
when you navigate in the area covered by this chart.
Failed automatic conversion: ENCD ROMK3EI0XE.000, edt: 1, upd: 0 / 1999 2 17
Failed conversion of an update
Chart is partly usable, but it is not up-to-date and you need the latest edition of the chart from its publisher. Note that
the chart is still ENC, but it no longer fulfils the SOLAS requirement. You must refer to a paper chart as legal
primary aid of navigation, when you navigate in the area covered by this chart.
Failed auto. conv: ENC: GB500005.001, edt: 2, upd: 1 / 1997 9 26 Updating impossible before
new edition of Base cell
Failed conversion. Checksum is not correct
Chart is not usable and you cannot view it. Try to reload the Base cell or update from the original media. And if that
doesn't work order a new CD ROM from your chart supplier. You must refer to a paper chart as legal primary aid of
navigation, when you navigate in the area covered by this chart.
Failed automatic conversion: ENC: SG5CONTL.000, edt: 1, upd: 0 / 1996 2 25 CHECKSUM ERROR
Failed conversion. Checksum of an update is not correct
Chart is partly usable, but it is not up-to-date. Try to reload the update from the original media. And if that doesn't
work order a new CD ROM from your chart supplier. Note that the chart is still ENC, but it no longer fulfils the
SOLAS requirement. You must refer to a paper chart as legal primary aid of navigation, when you navigate in the
area covered by this chart.
Failed automatic conversion: ENC: GB5X01SW.002, edt: 1, upd: 2 / 2005 1 1 CHECKSUM ERROR
Failed conversion. At least one of the previous updates has failed in its SENC conversion
The system cannot accept additional updates unless all previous updates have been successfully converted into the
SENC. Chart is partly usable, but it is not up-to-date. Try to reload the failed previous update from the original
media (in this example the failed previous update is GB5X01SW.002). And if that doesn't work, order a new CD
ROM from your chart supplier. Note that the chart is still ENC, but it no longer fulfils the SOLAS requirement. You
must refer to a paper chart as legal primary aid of navigation, when you navigate in the area covered by this chart.
Failed automatic conversion: ENC: GB5X01SW.003, edt: 1, upd: 3 / 2005 9 8 PREVIOUS Update
MISSING
Failed conversion. The Base cell has failed in its SENC conversion
The system cannot accept updates unless the Base cell has been successfully converted into the SENC. Chart is not
usable and you cannot view it. Try to reload the Base cell from the original media (in this example the failed Base
cell is GB5X01SW.000). And if that doesn't work, order a new CD ROM from your chart supplier. You must refer
to a paper chart as legal primary aid of navigation, when you navigate in the area covered by this chart.
Failed automatic conversion: ENC: GB5X01SW.001, edt: 1, upd: 1 / 1998 9 8 PREVIOUS Base CELL
OR Update MISSING
NOTE: Always study both the "Failed SENC conversion" dialog and "Conversion history log" very
carefully, because they contain important information about the legal status of the charts. Specially
note that a chart may lose its legal status to fulfil SOLAS requirements and you may need to refer to
a paper chart as legal primary aid of navigation.