4-12
alarm oam error-frame-seconds-summary
Syntax
alarm oam error-frame-seconds-summary { window window | threshold threshold } *
undo alarm oam error-frame-seconds-summary { window | threshold } *
View
OLT port view, ONU port view, FTTH view
Default Level
2: System level
Parameters
window window: Specifies the window size, in the range 100 to 9000 (in 100 ms). By default, the
window size is 600.
threshold threshold: Specifies the alarm threshold, in the range 1 to 900 (in seconds). By default, the
threshold is 1 second.
Description
Use the alarm oam error-frame-seconds-summary command to configure the corresponding
window size and alarm threshold.
Use the undo alarm oam error-frame-seconds-summary to restore the default window size and
alarm threshold.
The system generates an error frame seconds summary alarm when the number of error frame
seconds (in an error frame second, at least one error frame occurs) in a specific time period (for
example, 1 minute) exceeds the corresponding predefined threshold.
Related commands: alarm oam error-frame-seconds-summary enable.
The commands here take effect only for OAM 2.0 and above.
Examples
# Set the window size and alarm threshold for error frame seconds summary to 800 and 2 on ONU
1/0/1:1.
<Sysname> system-view
[Sysname] interface onu 1/0/1:1
[Sysname-Onu1/0/1:1] alarm oam error-frame-seconds-summary window 800 threshold 2
alarm oam error-frame-seconds-summary enable
Syntax
alarm oam error-frame-seconds-summary enable
undo alarm oam error-frame-seconds-summary enable
View