EasyManua.ls Logo

H3C S7500E Series

H3C S7500E Series
368 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-22
When congested, the interface sends a flow control frame to its peer.
Upon receiving a flow control frame from the peer, the interface suspends sending packets.
To implement flow control on a link, you must enable the generic flow control function at both ends of
the link.
Examples
# Enable flow control on interface GigabitEthernet 2/0/1.
<Sysname> system-view
[Sysname] interface gigabitEthernet 2/0/1
[Sysname-GigabitEthernet2/0/1] flow-control
flow-interval
Syntax
flow-interval interval
undo flow-interval
View
Ethernet interface view
Default Level
2: System level
Parameters
interval: Sets a statistics polling interval, in seconds. It ranges from 5 to 300 and must be a multiple of 5.
The default value is 300s.
Description
Use the flow-interval command to set the interface statistics polling interval.
Use the undo flow-interval command to restore the default interval.
Examples
# Set the statistics polling interval to 100 seconds on GigabitEthernet 2/0/1.
<Sysname> system-view
[Sysname] interface gigabitEthernet 2/0/1
[Sysname-GigabitEthernet2/0/1] flow-interval 100
group-member
Syntax
group-member interface-list
undo group-member interface-list
View
Port group view
Default Level
2: System level
Parameters
interface-list: Ethernet interface list, in the form of interface-type interface-number [ to interface-type
interface-number ] &<1-10>, where &<1-10> indicates that you can specify up to 10 ports or port
ranges.