20-22
Default level
2: System level
Parameters
value: TTL multiplier, in the range 2 to 10.
Description
Use the lldp hold-multiplier command to set the TTL multiplier.
Use the undo lldp hold-multiplier command to restore the default.
By default, the TTL multiplier is 4.
You can set the TTL of the local device information by configuring the TTL multiplier.
The TTL information of a device is determined by the following expression:
TTL multiplier × LLDPDU transmit interval
The TTL can be up to 65535 seconds. Longer TTLs will be rounded off to 65535 seconds.
Related commands: lldp timer tx-interval.
Examples
# Set the TTL multiplier to 6.
<Sysname> system-view
[Sysname] lldp hold-multiplier 6
lldp management-address-format string
Syntax
lldp management-address-format string
undo lldp management-address-format
View
Layer 2 Ethernet interface view, port group view
Default Level
2: System level
Parameters
None
Description
Use the lldp management-address-format string command to encapsulate the management
address in the form of strings in TLVs.
Use the undo lldp management-address-format command to restore the default.
By default, the management address is encapsulated in the form of numbers in TLVs.
Examples
# Configure GigabitEthernet 2/0/1 to encapsulate the management address in the form of strings in
management address TLVs.
<Sysname> system-view
[Sysname] interface gigabitethernet 2/0/1
[Sysname-GigabitEthernet2/0/1] lldp management-address-format string