4-2
Examples
# Configure OLT 1/0/1 to monitor only the uplink data between OLT and ONU, and set the alarm
threshold of bit error rate to 20.
<Sysname> system-view
[Sysname] interface olt 1/0/1
[Sysname-Olt1/0/1] alarm bit-error-rate direction uplink threshold 20
alarm bit-error-rate enable
Syntax
alarm bit-error-rate enable
undo alarm bit-error-rate enable
View
OLT port view, FTTH view
Default Level
2: System level
Parameters
None
Description
Use the alarm bit-error-rate enable command to enable the bit error rate alarm.
Use the undo alarm bit-error-rate enable command to disable the bit error rate alarm.
By default, the bit error rate alarm is enabled.
Examples
# Enable the bit error rate alarm on OLT 3/0/1.
<Sysname> system-view
[Sysname] interface olt 3/0/1
[Sysname-Olt3/0/1] alarm bit-error-rate enable
alarm device-fatal-error enable
Syntax
alarm device-fatal-error enable
undo alarm device-fatal-error enable
View
OLT port view, FTTH view
Default Level
2: System level
Parameters
None
Description
Use the alarm device-fatal-error enable command to enable the device fatal error alarm.
Use the undo alarm device-fatal-error enable command to disable the device fatal error alarm.
By default, the device fatal error alarm is enabled.

Table of Contents

Other manuals for H3C S7500E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S7500E Series and is the answer not in the manual?

H3C S7500E Series Specifications

General IconGeneral
BrandH3C
ModelS7500E Series
CategorySwitch
LanguageEnglish

Related product manuals