4-8
Related commands: alarm oam error-symbol-period enable.
When the upper limit and the lower limit of the alarm threshold are set to 0, large amount of alarms
are generated immediately. Since alarm events are carried in the OAM packets, large amount of
OAM packets are generated. In this case, OAM packets may be lost.
The commands here take effect only for OAM 2.0 and above.
Examples
# On ONU 1/0/1:1, set the higher window size, lower window size, higher alarm threshold, and lower
alarm threshold for the error symbol period alarm to 1, 3, 10, and 30 respectively.
<Sysname> system-view
[Sysname] interface onu 1/0/1:1
[Sysname-Onu1/0/1:1] alarm oam error-symbol-period window-high 1 window-low 3 threshold-high
10 threshold-low 30
alarm oam error-symbol-period enable
Syntax
alarm oam error-symbol-period enable
undo alarm oam error-symbol-period enable
View
OLT port view, ONU port view, FTTH view
Default Level
2: System level
Parameters
None
Description
Use the alarm oam error-symbol-period enable command to enable the error symbol period alarm.
Use the undo alarm oam error-symbol-period enable command to disable the error symbol period
alarm.
By default, the error symbol period alarm is enabled.
The commands here take effect only for OAM 2.0 and above.
Examples
# Enable the error symbol period alarm on ONU 3/0/1:1.
<Sysname> system-view
[Sysname] interface onu 3/0/1:1

Table of Contents

Other manuals for H3C S7500E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S7500E Series and is the answer not in the manual?

H3C S7500E Series Specifications

General IconGeneral
BrandH3C
ModelS7500E Series
CategorySwitch
LanguageEnglish

Related product manuals