4-18
View
FTTH view
Default Level
3: Manage level
Parameters
None
Description
Use the sample enable command to enable system statistics sampling.
Use the undo sample enable command to disable system statistics sampling.
By default, system statistics sampling is enabled.
Examples
# Enable statistics sampling in the EPON system.
<Sysname> system-view
[Sysname] ftth
[Sysname-ftth] sample enable
timer monitor
Syntax
timer monitor seconds
undo timer monitor
View
FTTH view
Default Level
3: Manage level
Parameters
seconds: Alarm monitor period, ranging from 1 to 3600 (in seconds). The system default is 80
seconds.
Description
Use the timer monitor command to configure the alarm monitor period of the system.
Use the undo timer monitor command to restore the default monitor period.
Examples
# Configure the alarm monitor period of the EPON system to 100 seconds.
<Sysname> system-view
[Sysname] ftth
[Sysname-ftth] timer monitor 100
timer sample
Syntax
timer sample seconds
undo timer sample

Table of Contents

Other manuals for H3C S7500E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S7500E Series and is the answer not in the manual?

H3C S7500E Series Specifications

General IconGeneral
BrandH3C
ModelS7500E Series
CategorySwitch
LanguageEnglish

Related product manuals