126 IconMaster Installation and Configuration Manual
Chapter 4: Router Connections
Initializing IconMaster
Once you have completed the system wiring, the following settings are
required:
• Network settings
• Operating standard
• System timing
Network Settings
The default IP address will function correctly in a “one frame and one panel”
configuration if both frame and panel are connected to the same switch that is
not connected to a network server or router.
If you have changed the IP address on the card edge of the MKE-3901 module,
you must make the same change in the Network dialog box in the ICU software
(see page 201).
To change the network settings of the IconMaster control panel, refer to the
Panel Network Configuration dialog box in ICU software (see page 209).
Alternatively, you can use the Service Menu change the IP address of the
IconMaster control panel on the panel itself. Refer to the IconMaster Functional
Operation and Configuration Manual for more information.
Operating Standard
To change the operating standard, use the Genlock and Standards dialog box in
the ICU software (see page 191).
System Timing
To make changes to the IconMaster timing, use the Genlock and Standards
dialog box in the ICU software (see page 191).