8.10.10.2 X23 Resolver Feedback
The diagram below shows the connection of a resolver (2 to 36-poles) as a feedback system. The thermal control in
the motor is connected via the Resolver cable and evaluated in the drive. If no thermal control is in the motor, the
cable must short pins 8 and 9.
If cable lengths of more than 100m are planned, please contact customer support.
Type FBx.INDENTIFIED Description
Resolver 40 Accuracy: 14 bit (0.022°), resolution: 16 bit (0.006°), frequency (fixed): 6875 Hz
*Resolver Sine/Cosine channels must be high impedance - DC termination switch open.
*DC termination is not compatible with the REFchannel - DC termination switch open.
AKD2G-S Installation Manual, Safety 1
Kollmorgen | kdn.kollmorgen.com | June, 2023 113