EasyManuals Logo

Kollmorgen AKD 2G-S Series User Manual

Kollmorgen AKD 2G-S Series
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #163 background imageLoading...
Page #163 background image
9.1 Important Notes
Only professional personnel with extensive knowledge in the fields of electrical engineering and drive
technology are allowed to test and set up the drive.
Lethal Voltage!
There is a danger of serious personal injury or death by electrical shock. Lethal danger exists at
live parts of the device.
l
Built-in protection measures such as insulation or shielding may not be removed.
l
Work on the electrical installation may only be performed by trained and qualified
personnel, in compliance with the regulations for safety at work, and only with switched
off mains supply, and secured against restart.
l
In normal operation, the cabinet door must be closed and the device must not be
touched.
Automatic Restart!
Risk of death or serious injury for humans working in the machine. The drive might restart
automatically after power on, voltage dip or interruption of the supply voltage, depending on the
parameter setting. If parameter AXIS#.ENDEFAULT is set to 1,
l
then place a warning sign ("WARNING: Possible Automatic Restart" or similar) to the
machine.
l
Ensure, that power on is not possible, while humans are in a dangerous zone of the
machine.
High Temperature!
Risk of minor burns. The heat sink of the drive can reach temperatures up to 80°C in operation.
l
Check the heat sink temperature before handling the drive.
l
Wait until the heat sink has cooled down to 40°C before touching it.
If the drive has been stored for more than 1 year, you must re-form the capacitors in the DC bus link circuit.
Re-forming procedures are described in the KDN (Forming).
Additional information on setting up the equipment:
l
Programming parameters and control loop behavior are described in the AKD2G User
Manual (Online Help), see Configuring the Command Source and Operating Mode.
l
The setup of any fieldbus is described in the corresponding manual on the DVD.
AKD2G-S Installation Manual, Safety 1
Kollmorgen | kdn.kollmorgen.com | June, 2023 163

Table of Contents