AKD2G-S Installation Manual, Safety 1 | 14 Requirements to User Documentation, Revision 1.12
ID
(green=done
for all FS)
Requirements
Realized
(green=done for FSx)
13849-13
— checking test intervals where
relevant.
FS1 (You must test the STO function after initial start of the axis,
after each intervention into the wiring of the system, or after
exchange of one or several components of the drive system. The
proof test interval is one year to meet the required PFH., ➜ # 183)
13849-14
— dated reference to this part of ISO
13849 (i.e. “ISO 13849-1:2006”);
FS1 (Standards, ➜ # 183)
13849-15
— the Category, B, 1, 2, 3, 4; FS1 (Safety Properties Overview, ➜ # 183)
13849-16
— the performance level, a,b,c,d,e. FS1 (Safety Properties Overview, ➜ # 183)
14.4 IEC 61508-3 Annex D Requirements to User Documentation
Not applicable, because the SMM software will not be identified as element which is sold separately. The SMM
software will always be distributed as part of FS2 or FS3.
14.5 Revisions
Revision Remarks
1.0 First edition
1.1 ISO 13849 and EN 61508 requirements added
1.2 14.1/2/3: Table Header: green marking explained
14.3: Column "Planned Content" removed.
14: Additional WIs added/updated referring to "9D00-0657_Map Safety Traceability report Kollmorgen" table.
14.1 WI numbers sorted.
1.3 14.1 WI-1373 added
14.1 WI-231 etc: altitude 2000 m
14.3 Fault exclusion and deviation entries added (from Map Safety Manual Plan 9D00-0620)
1.4 WI-834 / WI-1752 separate lines
WI-805 / WI-849 / WI-6536 added
formal improvements
WI-194 / WI-195 /WI-802 added
210 Kollmorgen | kdn.kollmorgen.com | June, 2023