15 Parameter reference
15.2 Parameter list
1036
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00997
C00998
C00999
C01000
Parameter | Name:
C00997 | SLPSM: Filter cutoff frequency
Data type: INTEGER_16
Index: 23578
d
= 5C1A
h
From version 10.00.00
Sensorless control for synchronous motors (SLPSM)
Setting range (min. value | unit | max. value) Lenze setting
0.00 % 100.00 5.00 %
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00998 | SLPSM: Filter time rotor position
Data type: INTEGER_16
Index: 23577
d
= 5C19
h
From version 10.00.00
Sensorless control for synchronous motors (SLPSM)
Setting range (min. value | unit | max. value)
0.5 ms 20.0
Subcodes Lenze setting Info
C00998/1 3.0 ms SLPSM
: Filter time rotor position
C00998/2 5.0 ms SLPSM
: Filter time actual speed value
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10
Parameter | Name:
C00999 | SLPSM: PLL gain
Data type: INTEGER_16
Index: 23576
d
= 5C18
h
From version 10.00.00
Sensorless control for synchronous motors (SLPSM)
Setting range (min. value | unit | max. value) Lenze setting
0 % 1000 400 %
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C01000 | MCTRL: Status
Data type: UNSIGNED_16
Index: 23575
d
= 5C17
h
From version 10.00.00
Display area (min. hex value | max. hex value)
0x0000 0xFFFF
Value is bit-coded: Info
Bit 0 SLPSM: Speed closed-loop control 1 The sensorless control for synchronous motors is in
the closed-loop controlled operation (|n
Setpoint
| >
n
C00996
).
Sensorless control for synchronous motors (SLPSM)
Bit 1 SLPSM: Speed open-loop control From version 12.00.00
1 The sensorless control for synchronous motors is in
the open-loop controlled operation (|n
Setpoint
| > n
C00996
).
Sensorless control for synchronous motors (SLPSM)
Bit 2 Motor ASM From version 12.00.00
1 Set motor type is "Asynchronous motor"
Bit 3 Motor PSM From version 12.00.00
1 Set motor type is "Synchronous motor"

Table of Contents

Other manuals for Lenze 8400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 and is the answer not in the manual?

Lenze 8400 Specifications

General IconGeneral
CategoryDC Drives
Series8400
Protection classIP20
Control TypeVector control
CommunicationCANopen, PROFIBUS, Ethernet
Protection FeaturesOvercurrent, overvoltage, undervoltage, overtemperature
Input VoltageAC 230/400/480 V

Related product manuals