15 Parameter reference
15.2 Parameter list
1044
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01049
C01050
C01051
C01052
Parameter | Name:
C01049 | L_CalcDiameter_1: Status
Data type: INTEGER_16
Index: 23526
d
= 5BE6
h
From version 11.00.00
Display range (min. value | unit | max. value)
-10 30
Subcodes Info
C01049/1 L_CalcDiameter_1
: Status
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C01050 | L_CalcDiameter_1: Diameter recalculation
Data type: UNSIGNED_32
Index: 23525
d
= 5BE5
h
From version 11.00.00
Setting range (min. value | unit | max. value)
0.001 Rev. 1000.000
Subcodes Lenze setting Info
C01050/1 1.000 rev. L_CalcDiameter_1
: Diameter recalculation 0
C01050/2 0.100 rev. L_CalcDiameter_1
: Diameter recalculation 1
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1000
Parameter | Name:
C01051 | L_CalcDiameter_1: Filter time constant
Data type: UNSIGNED_16
Index: 23524
d
= 5BE4
h
From version 11.00.00
Setting range (min. value | unit | max. value)
0.010 s 3.000
Subcodes Lenze setting Info
C01051/1 1.000 s L_CalcDiameter_1
: Filter time constant
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1000
Parameter | Name:
C01052 | L_CalcDiameter_1: Web break monitoring
Data type: INTEGER_16
Index: 23523
d
= 5BE3
h
From version 11.00.00
Setting range (min. value | unit | max. value)
0.00 % 100.00
Subcodes Lenze setting Info
C01052/1 10.00 % L_CalcDiameter_1
: Permissible diameter change
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100