15 Parameter reference
15.2 Parameter list
1048
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01064
C01065
C01066
Parameter | Name:
C01064 | L_SwitchPoint_1: CenterMode
Data type: UNSIGNED_8
Index: 23511
d
= 5BD7
h
From version 11.00.00
Selection list
0False
1True
Subcodes Lenze setting Info
C01064/1 0: FALSE L_SwitchPoint_1
: CenterMode 1
C01064/2 0: FALSE L_SwitchPoint_1
: CenterMode 2
C01064/3 0: FALSE L_SwitchPoint_1
: CenterMode 3
C01064/4 0: FALSE L_SwitchPoint_1
: CenterMode 4
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C01065 | L_SwitchPoint_1: Running time
Data type: UNSIGNED_16
Index: 23510
d
= 5BD6
h
From version 11.00.00
Setting range (min. value | unit | max. value)
0 ms 60000
Subcodes Lenze setting Info
C01065/1 0 ms L_SwitchPoint_1
: Running time 1
C01065/2 0 ms L_SwitchPoint_1
: Running time 2
C01065/3 0 ms L_SwitchPoint_1
: Running time 3
C01065/4 0 ms L_SwitchPoint_1
: Running time 4
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C01066 | L_SwitchPoint_1: Status
Data type: INTEGER_16
Index: 23509
d
= 5BD5
h
From version 11.00.00
Selection list
0 OK
10 FB not active
100 Switching points not plausible
Subcodes Info
C01066/1 L_SwitchPoint_1
: Status 1
C01066/2 L_SwitchPoint_1
: Status 2
C01066/3 L_SwitchPoint_1
: Status 3
C01066/4 L_SwitchPoint_1
: Status 4
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1