15 Parameter reference
15.2 Parameter list
1050
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01069
C01070
C01071
C01072
Parameter | Name:
C01069 | L_DFSET_1: Ramp settings
Data type: UNSIGNED_16
Index: 23506
d
= 5BD2
h
From version 11.00.00
Setting range (min. value | unit | max. value)
0 Incr./ms 32767
Subcodes Lenze setting Info
C01069/1 10 incr./ms L_DFSET_1
: Ramp SpeedTrim (1/100)
• From version 12.00.00 onwards, this setting has a
resolution increased by the factor 100: A value of
32767 is internally evaluated with 327.67. Hence, the
unit is [incr./100 ms].
C01069/2 100 incr./ms L_DFSET_1
: Ramp angle compensation
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C01070 | L_DFSET_1: Angular trimming
Data type: INTEGER_32
Index: 23505
d
= 5BD1
h
From version 11.00.00
Setting range (min. value | unit | max. value)
-134217728 Incr. 134217728
Subcodes Lenze setting Info
C01070/1 0 incr. L_DFSET_1
: Speed-dependent angle adjustment
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C01071 | L_DFSET_1: Following error limit
Data type: UNSIGNED_32
Index: 23504
d
= 5BD0
h
From version 11.00.00
Setting range (min. value | unit | max. value)
10 Incr. 2147483647
Subcodes Lenze setting Info
C01071/1 32768 incr. L_DFSET_1
: Following error limit
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C01072 | L_DFSET_1: Multiplier - angular trimming
Data type: INTEGER_16
Index: 23503
d
= 5BCF
h
From version 11.00.00
Setting range (min. value | unit | max. value)
-20000 20000
Subcodes Lenze setting Info
C01072/1 1 L_DFSET_1
: Multiplier - angular trimming
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1