Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23 1127
15 Parameter reference
15.2 Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02298
C02299
C02300
Parameter | Name:
C02298 | LS_WriteParamList: Flying restart fct: Int. time
Data type: UNSIGNED_16
Index: 22277
d
= 5705
h
From version 12.00.00 onwards: Parameter values (1st value ... 4th value) for optional motor data change-over
Setting range (min. value | unit | max. value)
0.0 ms 6000.0
Subcodes Lenze setting Info
C02298/1 300.0 ms LS_WriteParamList
: c993_val1
C02298/2 300.0 ms LS_WriteParamList
: c993_val2
C02298/3 300.0 ms LS_WriteParamList
: c993_val3
C02298/4 300.0 ms LS_WriteParamList
: c993_val4
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10
Parameter | Name:
C02299 | LS_WriteParamList: Flying restart fct.: Current
Data type: INTEGER_16
Index: 22276
d
= 5704
h
From version 12.00.00 onwards: Parameter values (1st value ... 4th value) for optional motor data change-over
Setting range (min. value | unit | max. value)
0.00 % 100.00
Subcodes Lenze setting Info
C02299/1 25.00 % LS_WriteParamList
: c994_val1
C02299/2 25.00 % LS_WriteParamList
: c994_val2
C02299/3 25.00 % LS_WriteParamList
: c994_val3
C02299/4 25.00 % LS_WriteParamList
: c994_val4
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C02300 | LS_WriteParamList: SLPSM: Controlled current setpoint
Data type: UNSIGNED_16
Index: 22275
d
= 5703
h
From version 12.00.00 onwards: Parameter values (1st value ... 4th value) for optional motor data change-over
Setting range (min. value | unit | max. value)
5.00 % 400.00
Subcodes Lenze setting Info
C02300/1 100.00 % LS_WriteParamList
: c995_s1_val1
C02300/2 100.00 % LS_WriteParamList
: c995_s1_val2
C02300/3 100.00 % LS_WriteParamList
: c995_s1_val3
C02300/4 100.00 % LS_WriteParamList
: c995_s1_val4
C02300/5 20.00 % LS_WriteParamList
: c995_s2_val1
C02300/6 20.00 % LS_WriteParamList
: c995_s2_val2
C02300/7 20.00 % LS_WriteParamList
: c995_s2_val3
C02300/8 20.00 % LS_WriteParamList
: c995_s2_val4
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100