6 I/O terminals
6.1 Digital input terminals
324
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Short overview of parameters for the digital input terminals:
Related topics:
Touch probe detection
( 357)
User-defined terminal assignment
( 365)
Parameters Info Lenze setting
Value Unit
C00115/1 Fct. DI 1/2 200kHz
Change function assignment
( 325)
0: DI1(6)=In / DI2(7)=In
C00115/2
Fct. DI 6/7 10kHz
Change function assignment
( 325)
0: DI1(6)=In / DI2(7)=In
Digital inputs DI1 ... DI7
C00114
DigInX: Inversion Bit coded
C02830/1...7
DI1...DI7: Debounce time 1: 0.25
C00443/1 DIx: Terminal level -
C00443/2 DIx: Output level -
Greyed out = display parameter