Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23 675
9 Diagnostics & error management
9.9 Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Ck05: Following error 1 [xx.0184.00153]
Ck06: Following error 2 [xx.0184.00154]
Ck07: Travel range limit exceeded [xx.0184.00155]
Ck08: Home position unknown [xx.0184.00156]
Ck09: Positioning mode invalid [xx.0184.08005]
Response (Lenze setting printed in bold) Setting: C00595/5 ( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause Remedy
MCK: Following error limit 1 (C01215/1) has been
exceeded.
Optimise control mode.
Increase following error limit.
Deactivate following error monitoring.
Response (Lenze setting printed in bold) Setting: C00595/6 ( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause Remedy
MCK: Following error limit 2 (C01215/2) has been
exceeded.
Optimise control mode.
Increase following error limit.
Deactivate following error monitoring.
Response (Lenze setting printed in bold) Setting: C00595/7 ( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause Remedy
MCK: The maximum travel distance has been exceeded.
The maximum travel distance is displayed in
C01213/1
.
Check profile parameters.
Deactivate travel range limit monitoring.
Response (Lenze setting printed in bold) Setting: C00595/8 ( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause Remedy
MCK: Home position is unknown. Perform homing.
Response (Lenze setting printed in bold) Setting: C00595/9 ( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause Remedy
MCK: The positioning mode defined via the
wPosProfileMode input is not supported.
Define a valid positioning mode.