15 Parameter reference
15.2 Parameter list
812
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00003
C00005
Parameter | Name:
C00003 | Status of last device command
Data type: UNSIGNED_8
Index: 24572
d
= 5FFC
h
Status of the device command executed last (C00002).
Note:
Before switching off the supply voltage after carrying out a device command, check whether the device command
has been carried out successfully via the status display!
Drive control (DCTRL)
: Device commands
Selection list (read only) Info
0 Successful Device command has been executed successfully.
1 Command unknown Device command implausible or unknown to the system.
2 Password protection Unauthorised access for requested device command.
Password protection
3 Time-out Device command could not be processed in the defined
time (timeout).
4 System fault
5 Command server assigned
6 Controller inhibit required
7 unexpected controller inhibit
10 Memory module binding error Device personalisation
11 Password too short Password protection
12 Wrong password
13 Password already set
14 Password not assigned
15 Incorrect checksum
30 Incorrect pole position identification
31 Pole position identification started
without encoder
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00005 | Application
Data type: UNSIGNED_16
Index: 24570
d
= 5FFA
h
Selection of the technology application
Selection list (Lenze setting printed in bold) Info
0 Wiring has changed This display appears if the FB interconnection has been
changed in the application level using the FB Editor.