15 Parameter reference
15.2 Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00002/23 0: Off / ready Identify motor parameters
• This device command serves to carry out automatic
motor parameter identification.
• The device command is only executed when the
inverter is in the "SwitchedOn" status.
• In order to identify the motor parameters, the
inverter must be enabled after this device command.
• From version 10.00.00 onwards, the identification
mode can be selected in C02867.
Automatic motor parameter identification
C00002/24 0: Off / ready Reserved
C00002/25 0: Off / ready Reserved
C00002/26 0: Off / ready CAN reset node
• Reinitialise "CAN on board" interface.
• Required when changing the baud rate, node address,
or identifiers.
"CAN on board" system bus
C00002/27 0: Off / ready Device search function
• From version 06.00.00
• This device command serves to optically locate an
inverter connected online (e.g. for maintenance
work).
Device search function
C00002/28 0: Off / ready Check MasterPin
• From version 06.00.00
Unlocking the inverter with a MasterPin
C00002/29 0: Off / ready Set binding ID
• From version 06.00.00
Device personalisation
C00002/30 0: Off / ready Delete binding ID
• From version 06.00.00
Device personalisation
C00002/31 0: Off / ready Set password
• From version 06.00.00
Password protection
C00002/32 0: Off / ready Check password
• From version 06.00.00
Password protection
C00002/33 0: Off / ready Delete password
• From version 06.00.00
Password protection
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00002 | Device command
Data type: UNSIGNED_8
Index: 24573
d
= 5FFD