15 Parameter reference
15.2 Parameter list
826
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00057
C00058
C00059
C00061
C00062
Parameter | Name:
C00057 | Maximum torque
Data type: UNSIGNED_32
Index: 24518
d
= 5FC6
h
Display of the maximum torque to be generated by the motor
The maximum torque to be generated by the motor depends on various factors, e.g. on Imax in motor mode
(C00022
) and the motor type used.
Display range (min. value | unit | max. value)
0.00 Nm 65000.00
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00058 | Output frequency
Data type: INTEGER_32
Index: 24517
d
= 5FC5
h
Display of the current output frequency
Display range (min. value | unit | max. value)
-1300.00 Hz 1300.00
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00059 | Appl.: Reference frequency C11
Data type: UNSIGNED_32
Index: 24516
d
= 5FC4
h
Display of the field frequency which corresponds to the reference speed set in C00011.
Display range (min. value | unit | max. value)
0.00 Hz 1300.00
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00061 | Heatsink temperature
Data type: INTEGER_16
Index: 24514
d
= 5FC2
h
Display of the current heatsink temperature
Display range (min. value | unit | max. value)
-50 °C 150
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00062 | Temperature inside the controller
Data type: INTEGER_16
Index: 24513
d
= 5FC1
h
From version 11.00.00
Display of the current temperature inside the controller
Display range (min. value | unit | max. value)
-200 °C 200
Subcodes Info
C00062/1 Interior temperature of CU
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1