Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23 893
15 Parameter reference
15.2 Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00435
C00436
C00437
Parameter | Name:
C00435 | OxU/I: Offset
Data type: INTEGER_16
Index: 24140
d
= 5E4C
h
Offset of the analog outputs
Analog terminals
Setting range (min. value | unit | max. value)
-199.99 % 199.99
Subcodes Lenze setting Info
C00435/1 0.00 % O1U: Offset
C00435/2 0.00 % O2U: Offset
C00435/3 0.00 % O1I: Offset
C00435/4 0.00 % O2I: Offset
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00436 | OxU: Voltage
Data type: INTEGER_16
Index: 24139
d
= 5E4B
h
Display of the voltage at the analog outputs
Analog terminals
Display range (min. value | unit | max. value)
0.00 V 10.00
Subcodes Info
C00436/1 O1U: Voltage
C00436/2 O2U: Voltage
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00437 | OxI: Current
Data type: INTEGER_32
Index: 24138
d
= 5E4A
h
Display of the current at the analog outputs
Analog terminals
Display range (min. value | unit | max. value)
0.000 mA 20.000
Subcodes Info
C00437/1 O1I: Current
C00437/2 O2I: Current
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1000