Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23 919
15 Parameter reference
15.2 Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00565
C00566
C00567
C00569
Parameter | Name:
C00565 | Resp. to mains phase failure
Data type: UNSIGNED_8
Index: 24010
d
= 5DCA
h
Response to the failure of mains phases
Selection list (Lenze setting printed in bold)
0 No Reaction
1Fault
5 Warning
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00566 | Resp. to fan failure
Data type: UNSIGNED_8
Index: 24009
d
= 5DC9
h
Response to the detection of a fan failure
Selection list (Lenze setting printed in bold)
0 No Reaction
1Fault
5 Warning
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00567 | Resp. to speed controller limited
Data type: UNSIGNED_8
Index: 24008
d
= 5DC8
h
Response if speed controller output is limited (bLimSpeedCtrlOut =TRUE)
Selection list (Lenze setting printed in bold)
0No Reaction
1Fault
5 Warning
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00569 | Resp. to peak current
Data type: UNSIGNED_8
Index: 24006
d
= 5DC6
h
Configuration of monitoring of the motor control (group 1)
Selection list
0 No Reaction
1Fault
5 Warning
Subcodes Lenze setting Info
C00569/1 0: No Reaction Response for overcurrent detection and clamp operation
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1