Page 61 of 237
Version: 5.1.6 – June 4
th
, 2018
Internet Settings > Settings
Internet Settings > Settings
Activate the checkbox if a connection to the Internet, initiated by data packets sent, is
to be established.
If this check box is activated, no connection that differs from the setting under "Con-
nection Mode" can be established. For example, a component connected to the LAN
uses the device (router) as a gateway.
Ignore traffic from
internal services
If this check box is activated, no connection that differs from the setting under "Con-
nection Mode" can be established. For example, if an e-mail is to be sent by the de-
vice (router) or an automatic time synchronization is to be executed.
If the connection to the Internet is to be triggered by pressing the Dial Out button on
the device front, activate this checkbox.
Connect on Sign 1 at
Input
don´t connect
Select this option if you do not want to set up an Internet connection, triggered
by a digital signal at one of the inputs.
Input 1, Input 2, Input 3, Input 4
Select this option if an Internet connection is to be established by a signal at
the corresponding input.
close connection
after inactivity of [s]
This is used to set the time for the existing Internet connection to be disconnected as
soon as data packets are no longer sent by the router. No input turns off this function.
For a detailed description of the Network – Internet settings, please see section Network – Internet
Save your changes by clicking Save Changes.
Click on System – User and add a user with dial-in rights. For further notes on adding users and assigning
specific rights, please see section Adding users