EasyManua.ls Logo

Mitutoyo HR-530 Series - Page 308

Mitutoyo HR-530 Series
356 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
No. 99MBG518A
J-2
PARTJ:1MainSpecications
Code HR-530 HR-530L
Code No. 810-233-20/810-233-21/810-233-23 810-333-20/810-333-21/810-333-23
Test force
(continued)
Brinell hardness test (indenting only)
Test force
N 61.29 980.7 153.2 245.2 294.2 306.5 612.9 980.7 1226 1839
(kgf) 6.25 10 15.625 25 30 31.25 62.5 100 125 187.5
Scale 1/10, 1/30, HB*2.5/6.25, 2.5/15.625, 2.5/31.25, 2.5/62.5, 2.5/187.5,
HB*5/25, 5/62.5, 5/125, HB*10/100
Plastic 1 hardness test
Preliminary test force Total test force
N 98.07 588.4 980.7 1471
(kgf) 10 60 100 150
Scale HRE*, HRL*, HRM*, HRR*, HRK*
Plastic 2 hardness test
Preliminary test force
Total test
force
N 98.07 588.4
(kgf) 10 60
Scale α-p
Indent depth Brinell hardness test
Preliminary test force Total test force
N
98.07 612.9 1839
(kgf) 10 62.5 187.5
Scale HBT2.5/62.5, HBT2.5/187.5
Test force loading
method
Electric drive motor (load, retain, unload)
Test force control Automatic (load, retain, unload)
Test force load
time
Preliminary test force from 1 through 2 seconds, total test force from 2 through
10 seconds (variable settings in 1-second increments)
Test force reten-
tion time
Preliminary test force from 1 through 120 seconds, total test force from 1 through
120 seconds, preliminary test force (after unloading) from 1 through 120 seconds
(variable settings in 1-second increments)
Test force unload
time
From 1 through 10 seconds (variable settings in 1-second increments)
Test force switch-
ing
Operation using display unit (touch panel)
Main unit electri-
cal power con-
sumption
30 W