C.1.3.2 MUs Cannot Associate and/or Authenticate with Access Ports
MUs cannot associate and/or authenticate with Access Ports.
The table below provides suggestions to troubleshoot this issue.
C.1.3.3 Poor Voice Quality Issues
VOIP MUs, BroadCast MultiCast and SpectraLink phones have poor voice quality issues. The table below
provides suggestions to troubleshoot this issue.
C.1.4 Miscellaneous Issues
This section describes various miscellaneous issues related to the Motorola RF Series Switch which don’t
fall into any of the previous categories. Possible issues include:
Excessive Fragmented Data or Excessive Broadcast
Excessive Memory Leak
C.1.4.1 Excessive Fragmented Data or Excessive Broadcast
Excessive fragmented data or excessive broadcast.
Possible Problem Suggestions to Correct
Preamble differences Verify that the preamble type matches between switch and MUs. Try a different
setting.
Device key issues Verify in Syslog that there is not a high rate of decryption error messages. This
could indicate that a device key is incorrect.
MU is not in Adopt List Verify the device is not in the “do not adopt ACL”.
Keyguard not set on client Verify Keyguard is set on the client if the Security/WLAN Policy calls for
Keyguard.
Encryption Problems If Encryption is being used, verify that the encryption settings on the MU and the
switch match.
If WEP Encryption is being used with non-Symbol or Motorola MUs, ensure that
the key being entered is in HEX format and not a Passphrase.
Authentication Problems If the switch is configured to use RADIUS authentication, check the RADIUS log
file for any failure information.
Encryption or
Authentication Problems
If you are using Authentication and/or Encryption on the switch, and the previous
troubleshooting steps have not fixed the problem, try temporarily disabling
Authentication and Encryption to see if that fixes the problem.
Possible Problem Suggestions to Correct
Traffic congestion with data
traffic
Maintain voice and data traffic on separate WLANs.
Use a QoS Classifier to provide dedicated bandwidth if data and voice traffic
are running on the same WLAN.
Long preamble not used on
Spectralink phones
Verify that a long preamble is used with Spectralink phones.

Table of Contents

Other manuals for Motorola RFS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motorola RFS Series and is the answer not in the manual?

Motorola RFS Series Specifications

General IconGeneral
BrandMotorola
ModelRFS Series
CategorySwitch
LanguageEnglish

Related product manuals