5-70 Motorola RF Switch System Reference
If the onboard SOLE engine is enabled to locate Aeroscout tags the following information will be displayed
for each located MU:
5.8.6 Configuring Ekahau Parameters
To configure the switch to work with an external Ekahau RTLS engine:
1. .Services > RTLS from the main menu tree.
2. Select the Ekahau tab.
3. Check the Enable checkbox to globally enable Ekahau support on the switch.
This takes effect immediately when the box is checked.
MAC Lists the MAC Addresses of all MUs which have been located by the switch.
Location:
X Coordinate
Displays the value of the X Coordinate for each located MU. The X coordinate is
relative to the origin point of 0,0 in the upper left corner of the site map.
Location:
Y Coordinate
Displays the value of the Y Coordinate for each located MU. The X coordinate is
relative to the origin point of 0,0 in the upper left corner of the site map.
Timestamp Displays the last time for each MU that its location was computed by the switch.
Zone Lists the last known zone for each located MU. Zone configuration can be defined
using the CLI interface only. When no zones are configured, the switch defaults
the entire site to Zone 0.
NOTE: Zone configuration can be defined using the CLI interface only. For information on Zone
Configuration please see the Motorola RF Switch CLI Reference.