EasyManuals Logo

Parker Compax3 I10T10 User Manual

Parker Compax3 I10T10
230 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #217 background imageLoading...
Page #217 background image
Parker EME
Technical Characteristics
192-120100 N16 C3I10T10 - December 2010
217
Resulting nominal and peak currents depending on the switching
frequency
Compax3MxxxD6 at 3*400VAC
Switching
frequency*
M050D6
M100D6
M150D6
M300D6
8kHz
I
nom
5A
rms
10A
rms
15A
rms
30A
rms
I
peak
(<5s) 10A
rms
20A
rms
30A
rms
60A
rms
16kHz
I
nom
3.8A
rms
7.5A
rms
10A
rms
20A
rms
I
peak
(<5s) 7.5A
rms
15A
rms
20A
rms
40A
rms
32kHz
I
nom
2.5A
rms
3.8A
rms
5A
rms
11A
rms
I
peak
(<5s) 5A
rms
7.5A
rms
10A
rms
22A
rms
Compax3MxxxD6 at 3*480VAC
Switching
frequency*
M050D6
M100D6
M150D6
M300D6
8kHz
I
nom
4A
rms
8A
rms
12.5A
rms
25A
rms
I
peak
(<5s) 8A
rms
16A
rms
25A
rms
50A
rms
16kHz
I
nom
3A
rms
5.5A
rms
8A
rms
15A
rms
I
peak
(<5s) 6A
rms
11A
rms
16A
rms
30A
rms
32kHz
I
nom
2A
rms
2.5A
rms
4A
rms
8.5A
rms
I
peak
(<5s) 4A
rms
5A
rms
8A
rms
17A
rms
The values marked with grey are the pre-set values (standard values)!
*corresponds to the frequency of the motor current
Resulting nominal and peak currents depending on the switching
frequency
Compax3HxxxV4 at 3*400VAC
Switching
frequency*
H050V4
H090V4
H125V4
H155V4
8kHz
I
nom
50A
rms
90A
rms
125A
rms
155A
rms
I
peak
(<5s) 75A
rms
135A
rms
187.5A
rms
232.5A
rms
16kHz
I
nom
33A
rms
75A
rms
82A
rms
100A
rms
I
peak
(<5s) 49.5A
rms
112.5A
rms
123A
rms
150A
rms
32kHz
I
nom
19A
rms
45A
rms
49A
rms
59A
rms
I
peak
(<5s) 28.5A
rms
67.5A
rms
73.5A
rms
88.5A
rms
Compax3HxxxV4 at 3*480VAC
Switching
frequency*
H050V4
H090V4
H125V4
H155V4
8kHz
I
nom
43A
rms
85A
rms
110A
rms
132A
rms
I
peak
(<5s) 64.5A
rms
127.5A
rms
165A
rms
198A
rms
16kHz
I
nom
27A
rms
70A
rms
70A
rms
84A
rms
I
peak
(<5s) 40.5A
rms
105A
rms
105A
rms
126A
rms
32kHz
I
nom
16A
rms
40A
rms
40A
rms
48A
rms
I
peak
(<5s) 24A
rms
60A
rms
60A
rms
72A
rms
The values marked with grey are the pre-set values (standard values)!
*corresponds to the frequency of the motor current

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker Compax3 I10T10 and is the answer not in the manual?

Parker Compax3 I10T10 Specifications

General IconGeneral
Rated Current10 A
Protection ClassIP20
Supply Voltage200-480 VAC
Control InterfaceEtherCAT, CANopen
Feedback OptionsResolver