EasyManuals Logo

Parker Compax3 I10T10 User Manual

Parker Compax3 I10T10
230 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #142 background imageLoading...
Page #142 background image
Setting up Compax3
C3I10T10
142
192-120100 N16 C3I10T10 - December 2010
4.4.7. Alignment of the analog inputs
Offset alignment
In this chapter you can read about:
.............................................................................................................142
Gain alignment ...............................................................................................................142
There are two possibilities to align the analog inputs in the optimization window:
 Wizard-guided under commissioning: Commissioning functions (click on the
yellow triangle with the left mouse button:
Caution!
This wizard guided automatic alignment does not work if you bridge Ain+ with
Ground for the alignment!
In this case, please make a manual alignment as described below.
or
 by directly entering under optimization: Analog input
4.4.7.1 Offset alignment
Performing an offset alignment when working with the ±10V analog interface in the
optimization window under optimization: Analog input Offset [170.4].
Enter the offset value for 0V input voltage.
The currently entered value is shown in the status value "analog input" (optimizing
window at the top right) (unit: 1 ≔ 10V). Enter this value directly with the same sign
as offset value.
The status value "analogue input" shows the corrected value.
4.4.7.2 Gain alignment
Performing an offset alignment when working with the ±10V analog interface in the
optimization window under optimization: Analog input: Gain [170.2].
A gain factor of 1 has been entered as default value.
The currently entered value is shown in the status value ā€œanalog inputā€ (optimizing
window at the top right).
The status value "analogue input" shows the corrected value.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker Compax3 I10T10 and is the answer not in the manual?

Parker Compax3 I10T10 Specifications

General IconGeneral
Rated Current10 A
Protection ClassIP20
Supply Voltage200-480 VAC
Control InterfaceEtherCAT, CANopen
Feedback OptionsResolver

Related product manuals