192-120100 N16 C3I10T10 - December 2010
Standard error reactions:
Reaction 2: Downramp with "de-energize" then apply brake (see on page 143)
and finally de-energize.
For errors with standard reaction 2 the error reaction can be changed (see on
page 109).
Reaction 5: deenergize immediately (without ramps), apply brake.
Caution! A Z-axis may drop down due to the brake delay times
Most pending errors can be acknowledged with Quit!
The following errors must be acknowledged with Power on:
0x7381, 0x7382, 0x7391, 0x7392, 0x73A0
Object 550.1 displays error:
value 1 means "no error".
The errors as well as the error history can be viewed in the C3 ServoManager
under optimization (at the top right of the optimization window).
7.1 Error list
Detailed information on the topic of the "error list" can be found in the online help of
the device.