M10 AT Commands Set
M10_ATC_V1.01 - 41 -
OK
Parameters
see Write Command
Response
TA controls the call forwarding supplementary service. Registration,
erasure, activation, deactivation, and status query are supported.
Only ,<reads> and <mode> should be entered with mode (0-2,4)
If <mode><>2 and Command successful
OK
If <mode>=2 and Command successful (only in connection with <reads> 0
3)
For registered call forward numbers:
+CCFC: <status>, <class1>[, <number>, <type>
[,<subaddr>,<satype>[,<time>]]] [<CR><LF>+CCFC: ....]
OK
If no call forward numbers are registered (and therefore all classes are
inactive):
+CCFC: <status>, <class>
OK
where <status>=0 and <class>=7
If error is related to ME functionality:
+CME ERROR: <err>
Write Command
AT+CCFC =
<reads>, <mode>
[, <number> [,
<type> [,<class>
[, <subaddr>
[,<satype>
[,time]]]]]]
Parameters
<reads>
0 unconditional
1 mobile busy
2 no reply
3 not reachable
4 all call forwarding (0-3)
5 all conditional call forwarding (1-3)
<mode>
0 disable
1 enable
2 query status
3 registration
4 erasure
<number> string type phone number of forwarding address in format
specified by <type>