No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
633
CTL
B
Counter device error 2
After 3 attempts to send a data frame to the optional counter device via the serial
communication line, no ACK signal was received within 100 ms.
• Serial line between the optional counter device, the relay board and copier
control board is disconnected or damaged
• Make sure that SP5113 is set to enable the optional counter device.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
634
CTL
B
Counter device error 3
A backup RAM error was returned by the counter device.
• Counter device control board defective
• Backup battery of counter device defective
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
635
CTL
B
Counter device error 4
A backup battery error was returned by the counter device.
• Counter device control board defective
• Backup battery of counter device defective
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
636 CTL SD Card Error
SC Tables