No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
910
CTL
D
External Controller Error 1
911 External Controller Error 2
912 External Controller Error 3
913 External Controller Error 4
914 External Controller Error 5
- - The external controller alerted the machine about an error.
- - • Please refer to the instructions for the external controller (application).
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
919
CTL
D
External Controller Error 6
While EAC (External Application Converter), the conversion module, was operating
normally, the receipt of a power line interrupt signal from the FLUTE serial driver was
detected, or BREAK signal from the other station was detected.
• Power outage at the EFI controller
• EFI controller was rebooted
• Connection to EFI controller loose
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
920
CTL
D
Printer application error
An error is detected in the printer application program.
• Defective software
• Unexpected hardware resource (e.g., memory shortage)
1. Software defective; switch off/on, or change the controller firmware if the
problem is not solved
2. Insufficient memory
3. Appendix: Service Call Conditions
108