017
Ends Temp. 4: –226 ENG [-10 to 10 / 0 / 1 deg/step]
Specifies the temperature correction for the heating roller (ends) when the paper width is less
than 226 mm.
The start time of this SP can be adjusted with SP1116-021.
018
Control Time 1: 226– ENG [0 to 250 / 60 / 1 sec/step]
Specifies the start time of the temperature correction that is set with SP1116-010 and -011.
The temperature correction is added when the time specified with this SP has passed after
feeding the paper.
019
Control Time 2: 226– ENG [0 to 250 / 0 / 1 sec/step]
Specifies the start time of the temperature correction that is set with SP1116-012 and -013.
The temperature correction is added when the time specified with this SP has passed after
feeding the paper.
020
Control Time 3: –226 ENG [0 to 250 / 60 / 1 sec/step]
Specifies the start time of the temperature correction that is set with SP1116-014 and -015.
The temperature correction is added when the time specified with this SP has passed after
feeding the paper.
021
Control Time 4: –226 ENG [0 to 250 / 0 / 1 sec/step]
Specifies the start time of the temperature correction that is set with SP1116-016 and -017.
The temperature correction is added when the time specified with this SP has passed after
feeding the paper.
022 M-Thick 1: Center Temp >=226 ENG
[-10 to 10 / 0 / 1 deg/step]
023 M-Thick 1: Ends Temp. >=226 ENG
024 M-Thick 2: Center Temp >=226 ENG
[-10 to 10 / 0 / 1 deg/step]
025 M-Thick 2: Ends Temp. >=226 ENG
026 M-Thick 3: Center Temp >=226 ENG [-10 to 10 / 0 / 1 deg/step]
027 M-Thick 3: Ends Temp. >=226 ENG [-10 to 10 / 5 / 1 deg/step]
028 M-Thick 4: Center Temp >=226 ENG
[-10 to 10 / 0 / 1 deg/step]
029 M-Thick 4: Ends Temp. >=226 ENG
System Service Mode