Language
Selects the instrument whose remote command set is emulated by the R&S SMBV.
The R&S SMBV can also be remote controlled via the command set of several other
generators, e.g. of an HP generator. You find the available command sets for the gen-
erator in the selection list. This feature allows to replace a generator by an R&S SMBV
in existing test setups. Refer to the corresponding Application Note at the download area
of the product site on the Internet. The Application Note is also provided on the user
documentation CD-ROM (included in delivery).
The selected instrument also defines the identification string that is retrieved with query
*IDN?. If required, use the parameter "Mode" and "IDN String" to change this string.
As any other parameter, the remote control command set can also be changed remotely
by means of the SCPI command SYST:LANG. However, this remote control command is
enabled only in the instrument's specific SCPI command set, i.e. it is possible to change
the command set remotely from the original one (SYST:LANG SCPI) to the command
set to be emulated but not vice versa.
Note: While working in a emulation mode, the R&S SMBV specific command set is dis-
abled, i.e. the SCPI command SYST:LANG will be discarded.
To return to the SCPI command set of the R&S SMBV, use the appropriate command of
the selected command set. If for example a HP generator is emulated, the HP command
EX returns to the instrument-specific GPIB command set.
SCPI command:
:SYSTem:LANGuage on page 715
General Instrument Settings