Remote Control Commands
R&S
®
SMBV100A
694Operating Manual 1407.6062.32 ─ 08
Tip: It is recommended to switch off the "GUI Update" for optimum sweep performance
especially with short dwell times (SYSTem:DISPlay:UPDate OFF).
Parameters:
<Dwell> float
Range: 10.0E-3 to 100
Increment: 100.0E-6
*RST: 10.0E-3
Default unit: s
Example:
SWE:DWEL 12 ms
sets a dwell time of 12 ms for a frequency sweep at the RF output.
[:
SOURce<hw>]:SWEep[:FREQuency]:EXECute
The command triggers a sweep.
The command is only valid for sweep mode Single (SOURce:SWEep:FREQuency:MODE
SINGle). The command corresponds to the manual-control command "Execute Single
Sweep".
Example:
SWE:FREQ:EXEC
triggers a frequency sweep at the RF output.
Usage: Event
[:SOURce<hw>]:SWEep[:FREQuency]:MODE <Mode>
Sets the sweep mode.
The keyword [:FREQuency] can be omitted (see example). The command is then
SCPI-compliant.
SOURce Subsystem