Guided Maintenance
Error Class 29 – Messages Concerning Board Communication
29-000 !error from COS-
MOS
COSMOS error. Set up a trace using infor-
mation from BLS.
Create a stack dump.
Save a snapshot.
29-010 !receive buffer not
free
Receive buffer is
not free.
Set up a trace using infor-
mation from BLS.
The board re-
ceive buffer can-
not receive mes-
sages from the
system (perfor-
mance prob-
lems).
29-014 !illegal pointer Invalid pointer. Set up IOP trace.
29-024 !polling time out The specified
board has malfunc-
tioned.
If this error persists, check
the board and the slot.
29-025 !card ist present-
LW has reset it-
self
Loadware of speci-
fied board restart-
ed.
If this error persists, check
the board and the slot.
29-035 !ELIC deadlock
no Interrupt from
ELIC
ELIC clock supply
malfunction.
Check clock supply.
Check central control
board.
Possible caus-
es:
● Faulty clock
supply
● Environmen-
tal influenc-
es
● Faulty con-
trol board
Error Class 30 – Board Software Messages
30-006 !XCSEPBC: PBC
error
PBC or ELIC error
on the specified
board.
Replace board.
30-016 !HEATER ON -
HXG3
Temperature in Hi-
Path 3550/HiPath
3350 wall housing
is too high.
Check the fan kit and the
air supply in the wall hous-
ing. Note the ambient tem-
perature.
Table 12-7 HiPath 3000 Class B Error Messages
No. HiPath 3000/
5000 Manager E:
Event Log Entry
Meaning Required Measures Note