System Programming Codes (Expert Mode Codes) Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
A-12 HiPath 3000/5000 V9, Service documentation
pcodes.fm
Accessing system administration
20 ISDN parameters
20 1 Call number suppression 0 = off, 1 = on
20 2 System station number - incoming
20 2 1 Station number; select trunk group
20 2 2 National number; select trunk group
20 2 3 International number; select trunk group
20 2 4 Type, outgoing; select trunk group:
0 = Unknown, 1 = Station, 2 = National, 3 = International, 4 = Internal
20 2 5 National prefix (U.S. = 1)
20 2 6 International prefix (U.S. = 011)
20 3 Reference clock
20 3 1 Allowed nos. list; select position (slot and port)
20 3 2 Denied nos. list; select position (slot and port)
20 4 EU parameters (not for U.S.)
20 4 1 S
0
port configuration; select slot/port and determine connection type (not
for U.S.):
1 = Automatic
2 = Euro CO PP
3 = Euro CO PMP
4 = Euro bus
5 = CorNet 1
6 = CorNet 2
7 = ECMA-QSIG
8 = ISO-QSIG
20 4 2 S2M port configuration; select slot/port and determine connection type
(not for U.S.):
1 = Euro CO PP
2 = CorNet 1
3 = CorNet 2
4 = ECMA-QSIG
5 = ISO-QSIG
20 4 3 S
0
bus MSN (for verification purposes only)
20 4 4 Call forwarding PMP
20 4 4 1 Multiple subscriber numbers, select index, 1 to 10
20 4 4 2 MSN trunks, select index, 1 to 10
Table A-3 Expert Mode Codes
Code Function

Table of Contents