pcodes.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
A-13
Nur für den internen Gebrauch System Programming Codes (Expert Mode Codes)
Accessing system administration
20 5 US parameters (for U.S. only)
20 5 1 BRI parameter
20 5 1 1 CO/protocol:
1 = AT&T/NI 1
2 = AT&T/Custom
3 = Siemens/NI 1
4 = NT/NI 1
20 5 1 2 SPID admin, select station, select slot/port
20 5 1 3 CAID admin, stn., select CAID
20 5 1 4 PDID admin, stn., select PDID
20 5 1 5 FIN - for message waiting
20 5 1 6 CACH EKTS, select slot/port: 0 = off, 1 = on
20 5 2 PRI parameters
20 5 2 11 Protocol type:
11 = AT&T/Custom
12 = AT&T/NI2
13 = AT&T/NI2 OSA
14 = AT&T/4ESS
15 = Siemens/Custom
16 = Siemens/Custom OSA
17 = Siemens/NI2
18 = Siemens/NI2 OSA
19 = MCI/DEX600
20 = MCI/DMS250
21 = BELL/DMS100
22 = BELL DMS100 TNS
23 = Nortel/DMS100
24 = Nortel DMS100 TNS
25 = SPRINT/DMS250
26 = Westinghouse
27 = FTS/DMS250
28 = FTS/5ESS
29 = GENERIC/NI2
30 = GENERIC/NI2 OSA
31 = QSIG
32 = IDA-P
Table A-3 Expert Mode Codes