A-17
Nur für den internen Gebrauch System Programming Codes (Expert Mode Codes)
Accessing system administration
20 6 1 System number
20 6 2 Group number
20 7 Keypad dial: 0 = denied, 1 = allowed
20 8 System station number - outgoing
20 8 1 Port number
20 8 2 National number
20 8 3 International number
20 8 4 Suppress station number
21 Analog CO interface
21 1 Dialing method; select slot/trunk:
0 = Automatic,
1 = DTMF,
2 = Dial pulses
3 = MFC-R2,
4 = MFC-R2 with OAD
21 2 Delayed dialing; select trunk group:
0 = No pause, 1 = 1 s, 2 = 3 s, 3 = 6 s, 4 = 9 s
21 3 Trunk call pause; select trunk group: 1 = 6 s, 2 = 13 s
21 4 Line Length; select slot and trunk: 0 = Short 1 = Long
21 5 Charge data module, select slot/trunk: 0 = off, 1 = on
21 6 Silent reversal: 0 = no, 1 = yes
21 7 Port status: 0 = on, 1 = Off (SW), 2 = Off (HW), 3 = Off (HW, SW)
21 8 Allocated without extension
22 System settings
22 11 Music on Hold (MOH): 0= Off, 1 = No ring tone, 2 = Ring tone, 3 = An-
nouncement device 1
22 12 Internal Phonebook: 0 = No, 1 = Internal, 2 = LDAP, 3 = All
22 13 V.24 (RS-232) configuration
22 13 1 Select CB baud rate: 1 = 9600 baud, 2 = 2400 baud, 3 = 19200 baud
22 13 2 Port assignment
22 13 2 1 CSTA/CDRC (call detail recording central), output: 0 = none, 1 = V.24
port, 2 = UPN port, 3 = PC-VPL, 4 = LAN
Table A-3 Expert Mode Codes