Codes for Activating/Deactivating Features Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
B-18 HiPath 3000/5000 V9, Service documentation
fcodes.fm
Call forward-
ing after time
on
*495 75495 *495 V, T RH U1 Fea-
ture
key
AN, DIG, ENT,
S0, CMI, IPSC
X RK,
BS
Call forward-
ing after time
off
#495 76495 #495 V, T RH U1 Fea-
ture
key
AN, DIG, ENT,
S0, CMI, IPSC
X RK,
BS
Extending un-
dialed lines
WA DIG Only for authorized
stations
AC call (see
numbering
plan)
9 (ROW)
0 (USA)
9 (ROW)
0 (USA)
9
(ROW
)
0
(USA)
9
(ROW)
0
(USA)
ALL
Redial Redial key X Local
feature
AN, DIG, ENT,
S0, CMI, IP-
SC, IPSI
X Cannot be pro-
grammed under
DSS.
Retrieval of
external call
placed on
common hold
*63+Trunk code 7563.. *63.. V H Local
feature
menu
AN, DIG, ENT,
S0, CMI, IPSC
Retrieval also possi-
ble with trunk key
Central tele-
phone lock
*943+Stn. no.+
* or #
75943.. *943.. U H AN, DIG, ENT,
S0, CMI, IPSC
X Only for authorized
stations
Return to held
call
(exclusive hold
off)
*0 or
CMI, DTMF:
Flash
TDM WpC with-
out display:
Consultation
hold key
Retrieve *0 BR,
WA,
RG,
GS,
BS
U1 Mouse
click,
key
AN, DIG, ENT,
S0, CMI, IP-
SC, IPSI
1 The codes are valid for DTMF telephones. Substitution codes 75 and 76 must be entered instead of “*” and “#” for DP tele-
phones.
Table B-1 Codes for Activating/Deactivating Features
Feature
Operating procedure for
Supported
workpoint cli-
ents
(see abbrevi-
ations in
Table B-2)
Locking of
feature
Note
TDM work-
point clients
without dis-
play,
CMI mobile
phones,
analog work-
point clients
1
S
0
work-
point cli-
ents
TDM workpoint clients with
display,
CMI feature mobile phones,
IP workpoint clients
OpenScape
Personal Edition
Code +
Procedure
Code
Code
Key Menu
Code
via
Telephone lock
Status
locking on
Fixed
Programm-
able
Dialog
Service
Abbreviations:
Call states: RH = idle, BR = ready, WA = digit input, BS = busy, RK = incoming call, RG = outgoing call, GS = call
Key programming: V = key can be programmed with complete feature, U = key can be programmed to start procedure, T = key with
toggle functionality
Menu level: H = Main menu, U1 = 1st submenu, U2 = 2nd submenu