Boards for HiPath 3000 Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
3-386 HiPath 3000/5000 V9, Service documentation
boards.fm
Options
Table 3-183 REALS - SIVAPAC Connector Assignment on the Backplane
Pair
a-wire
(tip)
1
b-wire
(ring)1
SIVAPAC Connec-
tor X116
REALS MDFU-E Notes
1
wht/blu 20 M48VF1 1a – 48 V (max. 300 mA)
blu/wht 38 0V_F 1b
2
wht/ora 18 PFTTLb 2a
ALUM: Subscriber line
(telephone)
ora/wht 17 PFTTLa 2b
3
wht/grn 16 0 V 3a
grn/wht 15 3b
4
wht/brn 14 0V_F 4a
brn/wht 13 M48VF2 4b – 48 V (max. 300 mA)
5
wht/gry 12 5a
gry/wht 11 0 V 5b
6
red/blu 10 AK1 6a
Relay 1: Normally open
contact
blu/red 9 AK2 6b
Relay 2: Normally open
contact
7
red/ora 8 AK3 7a
Relay 3: Normally open
contact
ora/red 7 AK4 7b
Relay 4: Normally open
contact
8
red/grn 6 0 V 8a
grn/red 5 PFTASa 8b
ALUM: Trunk module
9
red/brn 4 PFTASb 9a
brn/red 3 PFTALa 9b
ALUM: Trunk
10
red/gry 2 PFTALb 10a
gry/red 1 10b
11
blk/blu 37 11a
blu/blk 36 0 V 11b
12
blk/ora 35 12a
ora/blk 34 12b
13
blk/grn 32 RK3 13a
grn/blk 31 0 V 13b
14
blk/brn 30 RK1 14a
brn/blk 29 RK2 14b