System Data Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
2-30 HiPath 3000/5000 V9, Service documentation
sysdat.fm
HiPath 3000
Options
Table 2-13 Optional Boards for HiPath 3550
Board
Name
Capacity Coun-
try
Type/Description
ROW
USA
ALUM4 Trunk failure
transfers
4 x x Trunk failure transfer lets you transfer loop start
trunks directly to internal analog stations in the event
of a power failure (note the signaling method used).
ANI4 Analog
trunks
4 - x This board allows calling line identification (caller ID)
in conjunction with TMGL4.
GEE12 Number of call
charge receiv-
ers
4 x - This optional board records the country-specific call
charge pulses (12 kHz) from the trunk.
GEE16 Number of call
charge receiv-
ers
4 x - This optional board records the country-specific call
charge pulses (16 kHz) from the trunk.
GEE50 Number of call
charge receiv-
ers
4 x - This optional board records the country-specific call
charge pulses (50 Hz) from the trunk.
V24/1 1 x x One serial V.24 interface for connecting a PC, print-
er, or Plus Products.
STBG4 x - Current-limiting module for LS interface (France
only)
EXM 1 x - External music on hold
EXMNA Ports 1 - x External music on hold (A-LAW)
MPPI (Product of
BEYERTONE GmbH), or
MUSIC (Product of
Sound Player GmbH)
x - Music on hold (MOH)
UAM x - Announcement before answering/music on hold/re-
lay/sensor
STRB Sensors 4 x x Control relay module; provides 4 relays and 4 sen-
sors for controlling external devices or detecting ex-
ternal control events.
Relay 4