98
394149/C
Itisstronglyrecommendedtolayasteelconduitfromthecableglandabovethetransducer
totheEK80transceiver,andtopullthetransducercablethroughthisconduit.
Thereareseveralreasonsforthis.
•Itwillmakeiteasieratalaterstagetoreplacethetransducer.
•Itwillprotectthecables.
•Noiseandinterferencefromotherelectricalequipmentisgreatlyreduced.
•Theriskofoodingisgreatlyreducedwhenthesteelconduitisterminatedabovethe
waterline.
WithasteelconduittheinstallationwillsatisfytheEuropeanUnionregulationsfor
electromagneticcompatibility(EMC)interference.Withoutasteelconduit,thereisariskof
reducedEK80performance.
Procedure
1Obtainthewiringinformationforthetransduceryouwishtouse,aswellastherelevant
transducerconnectiondiagram.
2Prepareasteelconduitforthetransducercable.
3Pullthetransducercablethroughthesteelconduit.
4Connecttheconductorsinthetransducercabletothecorrectpinsintheplug.
Relatedtopics
Splitbeamtransducerconnectiontoacircularsocket,page120
SplitbeamtransducertosinglebeamoutputonGPTTransducersocket,page121
Simrad12-16/60connectiontoacirculartransducersocket,page123
SimradES18connectiontoacirculartransducersocket,page124
SimradES38-7connectiontoacirculartransducersocket,page125
SimradES30-10connectiontoacirculartransducersocket,page126
SimradES38-18/200-18Cconnectiontoacirculartransducersocket,page128
Simrad50/200CombiCconnectiontoacirculartransducersocket,page129
SimradES70-18CDconnectiontoacirculartransducersocket,page131
Usingasteelconduittoprotectthetransducercable,page105
SimradEK80