394149/C
31
Youmayplacethetwodisplaysnexttoeachother.Youmayalsochoosetoplacethe
seconddisplayatanotherlocationonthevessel.Thepresentationontheseconddisplayis
controlledusingtheoperatingsystemfeaturesontheProcessorUnit.
AnycommercialdisplaycanbeusedwiththeEK80Widebandscienticechosounder,
providedthatthedisplaymeetstheminimumrequirements.Thechosendisplaymustbe
designedformaritimeuse,anditmustmeettheminimumperformancespecications.
Youmustalsomakesurethatthechosendisplaysupportsthevideoformatsprovidedby
theProcessorUnit.
Tip
IfyoualsowishtocontroltheEK80fromthissecondarydisplaylocation,youcanadd
anextraOperatingPanel.
KongsbergMaritimemayprovideasuitabledisplay.Consultyourlocaldealeroragentfor
moreinformation.
Item
Ordernumber
Inthebox
Display335513
•DisplayHattelandJH19T14(19-inch,
1280x1024)
•Powercable
•Documentation
Mountinghardware339785
UninterruptiblePowerSupply(UPS)
ItisimportanttoensurecontinuousoperationoftheEK80independentofvaryingquality
ofthevessel'smainssupply.Theuseofanuninterruptiblepowersupplyistherefore
recommended.
UninterruptiblepowersupplyunitsarenotincludedinthestandardEK80delivery.These
itemsmustbepurchasedlocally.
Severalcommercialtypesareavailable.TochoosethebestpowersolutionforyourEK80
installation,considerenvironmentalconditions,spaceavailable,theavailabilityandduration
ofthebatteries,andthepowerrequirementsoftheEK80.
Theminimumspecicationsfortheuninterruptiblepowersupplyare:
•Inputvoltage:Theinputvoltagemusttvesselsupplyvoltage
•Outputvoltage:230V AC,50Hz
•Outputpower:TheoutputpowermustexceedtherequirementsoftheEK80
•Outputform:TheoutputACvoltagemustbeasinewave
SimradEK80