NetClock units produced before 2016 may not be equipped with the oscillator sensor. They
can be retrofitted, if so requested. For additional information, contact Technical Support (see
"Technical Support" on page429). As the front panel cooling fan is internal temperature con
trolled, the fan may not always be in operation. However, the fan may momentarily turn on
each time NetClock is power-cycled.
Units produced since 2016
Units produced since 2016 are often equipped with the Fan Control feature, which turns ON
the fan by default. This feature also allows for a custom temperature window to be set for the
fan.
Fan Control Feature
The Web UI Fan Control feature allows you to define a temperature range for the fan to turn
OFF and ON.
Note: Units produced before Dec. 2015 are not equipped with the Fan Control
feature.
Does my unit have Fan Control?
To find out, navigate to the HOME screen. Your unit is equipped with the Fan Control
feature, if there is a GEAR icon displayed in the System Status panel:
To enable user-defined Fan Control:
The default fan setting is ALWAYS ON.
To apply custom fan temperature settings:
4.5 Quality Management