Inter-integrated circuit (I
2
C) interface RM0090
842/1731 DocID018909 Rev 11
For N >2 -byte reception, from N-2 data reception
Wait until BTF = 1 (data N-2 in DR, data N-1 in shift register, SCL stretched low until
data N-2 is read)
Set ACK low
Read data N-2
Wait until BTF = 1 (data N-1 in DR, data N in shift register, SCL stretched low until a
data N-1 is read)
Set STOP high
Read data N-1 and N
27.3.4 Error conditions
The following are the error conditions which may cause communication to fail.
Bus error (BERR)
This error occurs when the I
2
C interface detects an external Stop or Start condition during
an address or a data transfer. In this case:
the BERR bit is set and an interrupt is generated if the ITERREN bit is set
in Slave mode: data are discarded and the lines are released by hardware:
in case of a misplaced Start, the slave considers it is a restart and waits for an
address, or a Stop condition
in case of a misplaced Stop, the slave behaves like for a Stop condition and the
lines are released by hardware
In Master mode: the lines are not released and the state of the current transmission is
not affected. It is up to the software to abort or not the current transmission
Acknowledge failure (AF)
This error occurs when the interface detects a nonacknowledge bit. In this case:
the AF bit is set and an interrupt is generated if the ITERREN bit is set
a transmitter which receives a NACK must reset the communication:
If Slave: lines are released by hardware
If Master: a Stop or repeated Start condition must be generated by software
Arbitration lost (ARLO)
This error occurs when the I
2
C interface detects an arbitration lost condition. In this case,
the ARLO bit is set by hardware (and an interrupt is generated if the ITERREN bit is
set)
the I
2
C Interface goes automatically back to slave mode (the MSL bit is cleared). When
the I
2
C loses the arbitration, it is not able to acknowledge its slave address in the same
transfer, but it can acknowledge it after a repeated Start from the winning master.
lines are released by hardware

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the STMicroelectronics STM32F405 and is the answer not in the manual?

STMicroelectronics STM32F405 Specifications

General IconGeneral
BrandSTMicroelectronics
ModelSTM32F405
CategoryController
LanguageEnglish

Related product manuals