RM0090 Serial peripheral interface (SPI)
918
Start sequence in master mode
In full-duplex (BIDIMODE=0 and RXONLY=0)
The sequence begins when data are written into the SPI_DR register (Tx buffer).
The data are then parallel loaded from the Tx buffer into the 8-bit shift register
during the first bit transmission and then shifted out serially to the MOSI pin.
At the same time, the received data on the MISO pin is shifted in serially to the 8-
bit shift register and then parallel loaded into the SPI_DR register (Rx buffer).
In unidirectional receive-only mode (BIDIMODE=0 and RXONLY=1)
The sequence begins as soon as SPE=1
Only the receiver is activated and the received data on the MISO pin are shifted in
serially to the 8-bit shift register and then parallel loaded into the SPI_DR register
(Rx buffer).
In bidirectional mode, when transmitting (BIDIMODE=1 and BIDIOE=1)
The sequence begins when data are written into the SPI_DR register (Tx buffer).
The data are then parallel loaded from the Tx buffer into the 8-bit shift register
during the first bit transmission and then shifted out serially to the MOSI pin.
No data are received.
In bidirectional mode, when receiving (BIDIMODE=1 and BIDIOE=0)
The sequence begins as soon as SPE=1 and BIDIOE=0.
The received data on the MOSI pin are shifted in serially to the 8-bit shift register
and then parallel loaded into the SPI_DR register (Rx buffer).
The transmitter is not activated and no data are shifted out serially to the MOSI
pin.
Start sequence in slave mode
In full-duplex mode (BIDIMODE=0 and RXONLY=0)
The sequence begins when the slave device receives the clock signal and the first
bit of the data on its MOSI pin. The 7 remaining bits are loaded into the shift
register.
At the same time, the data are parallel loaded from the Tx buffer into the 8-bit shift
register during the first bit transmission, and then shifted out serially to the MISO
pin. The software must have written the data to be sent before the SPI master
device initiates the transfer.
In unidirectional receive-only mode (BIDIMODE=0 and RXONLY=1)
The sequence begins when the slave device receives the clock signal and the first
bit of the data on its MOSI pin. The 7 remaining bits are loaded into the shift
register.
The transmitter is not activated and no data are shifted out serially to the MISO
pin.
In bidirectional mode, when transmitting (BIDIMODE=1 and BIDIOE=1)
The sequence begins when the slave device receives the clock signal and the first
bit in the Tx buffer is transmitted on the MISO pin.
The data are then parallel loaded from the Tx buffer into the 8-bit shift register
during the first bit transmission and then shifted out serially to the MISO pin. The

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the STMicroelectronics STM32F405 and is the answer not in the manual?

STMicroelectronics STM32F405 Specifications

General IconGeneral
BrandSTMicroelectronics
ModelSTM32F405
CategoryController
LanguageEnglish

Related product manuals