EasyManua.ls Logo

Studer Vista 1 - Monitoring;Talkback Inputs;Outputs; Vista 1 Mono;Stereo;Foh;Monitor Configuration Templates

Studer Vista 1
401 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Vista 1 Digital Mixing System
DSP Congurations 6-7
Document generated: 18.04.17
SW V5.3
6.3 Monitoring/Talkback Inputs/Outputs
6.3.1 ‘Vista 1 Mono/Stereo/FOH/Monitor’ Configuration Templates
The monitoring and TB I/O connector assignment for the mono, stereo and
PA configurations is identical, according to the information given below.
CR Mon PFL / Nearfields
Studio B Mon
Studio A Mon
CR Mon Main (L/R)
TB Mic
Mon Insert Send
CR Meter
Mon Insert Return
Format Analog I/O Digital I/O
CR Mon Main stereo LineOut 25, 26 -
OUTPUTS
CR Mon
PFL/Nearelds
stereo LineOut 31, 32 -
CR Meter stereo - AES Out 5/6 (inactive)
Studio A Mon stereo LineOut 27, 28 -
Studio B Mon stereo LineOut 29, 30 -
Studio A Meter - -
Studio B Meter - -
Mon Insert Send stereo - AES Out 15/16 (inactive)
Mon Insert Return stereo - AES In 15/16 (inactive)
INPUTS
TB Mic mono Mic/Line In 32 (inactive) -
Items marked by (inactive) in the table and in white in the drawing above
are preconfigured in the mon.ini file; they can be activated by deleting the
corresponding comment marks.

Table of Contents

Other manuals for Studer Vista 1

Related product manuals